Veterinarian Advanced Digital Radiographic
(DR) X-Ray

The Raymax Veterinarian System features digital radiography
(DR), a high frequency generator, and a 4 way float table. It is
an affordable complete Digital Radiography (DR) solution with
superior quality.
|
Features/Specifications:
- Height = 31 inches
- Length = 60 inches
- Width = 28 inches
- Cross Table Travel = 8 inches
- Longitudinal Table Travel = 14
inches
- Space Requirement = 6 x 9 feet
- Vertical SID Fixed 40 inches.
|
 |
| |
|
| Specs |
|
| Detector Type: |
16 Mega Pixel KODAK extreme KAF
series CCD Detector Chip. |
| Optical
Specification: |
Exclusive Leading Edge Optical Array
with Breakthrough Light Transfer and Distortion
Elimination Capability Using NO Mirrors. |
| Resolution: |
4096 x 4096 Pixels Overall Imaging
Resolution. Minimum 4.6 Line Pair per mm Resolution. |
| Acquisition
Time: |
Approximately 3 to 5 Seconds From
Exposure to Displayed Image. |
| Recycle Time: |
Zero Time Lag Between Subsequent
Image Acquisitions.
|
| Scintillation
Screen: |
Cesium Iodide (CsI). |
| Active Image
Area: |
40.5 x 40.5 cm Active Area (43 x 43
cm Optional). |
| Operating
Environment: |
Windows XP Based Acquisition and
Review Software Module. |
|
DICOM Format: |
Full DICOM 3.0 “Push/Pull”
Connectivity to HIS/RIS and Practice Management Systems.
Easy to Burn CD with on Board Auto Launching Mini
Viewer. |
Computer Workstation Minimum Required Specifications:
- 3.0 GHz Intel CPU
- 2 GB High Speed RAM
- 500 GB Hard Disk Drive @ 7200 RPM
- Independent PCI Video Graphics Card (512
MB)
- DVD/CD Drive @ 16 RW with Nero 7.0 + BURN
- Windows XP Professional Operating System
Monitor Minimum Required
Specifications:
- 2 MB High Contrast 1600 x 1200
- 21 inch Display

Generator
Specifications:
20 or 30 KW High Frequency Generator with Anatomical Programs.
 |
- Higher frequency for
reduced radiation exposure.
- Separate generator cabinet
and operator's console
- Tube protection circuit.
- Compact high voltage
transformer is fitted in the
generator cabinet.
- Optional APR (easy preset
techniques by anatomical
region selection) operator
console.
-
Optional AEC (automatic
exposure console).
-
Optional Buckey Control.
|
| Specs |
HF |
| Output Power
Technique Factors |
20 or 30 kW
400 mA, 125 kVp |
mA Range
kVp Range
Time |
25 to 400 mA
40 to 125 kVp
2ms to 6 sec. |
| Input Power |
Single Phase
188/250 VAC
65A Breaker |
| Weight
(Cabinet) |
150lb (68kg)
|
Brochure
|
The brochure is available in high
quality pdf format for printing. Each image will
open in a new window in adobe acrobat. Please
select an image to the right to begin. Please note
that the images are high quality and will require a high
speed connection for faster download.
|
 |
 |
| |
Brochure Front
pdf format
2.3 MB |
Brochure Back
pdf format
2.6 MB |
|