Veterinarian ECO21 Digital Radiographic (DR) X-Ray

The Raymax Veterinarian System features digital radiography (DR), a high frequency generator, and a 4 way float table. It is an affordable complete Digital Radiography (DR) solution with superior quality. 

 

Features/Specifications:

 

- Height = 31 inches

- Length = 60 inches

- Width = 28 inches

- Cross Table Travel = 8 inches

- Longitudinal Table Travel = 14 inches

- Space Requirement = 6 x 9 feet

- Vertical SID Fixed 40 inches.

Vet Eco21 table
   

 

DR Specifications:

 

 

Specs  
Detector Type: 21 Mega Pixel CMOS Detector Chip.
Optical Specification: High Quality 35 mm Optical Array.
Resolution: Minimum 2.8 Line Pair per mm Resolution.
Acquisition Time:   Approximately 8 to 12 Seconds From Exposure to Displayed Image.
Recycle Time:  Zero Time Lag Between Subsequent Image Acquisitions.
Scintillation Screen: Gadox (Gadolinium Oxysulfide).
Active Image Area:   33 x 43 cm.
Operating Environment:  Windows XP Based Acquisition and Review Software Module.
   DICOM Format: DICOM 3.0 based image database (DICOM send).


 

Computer Workstation Minimum Required Specifications:

 

- 3.0 GHz Intel CPU

- 2 GB High Speed RAM

- 500 GB Hard Disk Drive @ 7200 RPM

- Independent PCI Video Graphics Card (512 MB)

- DVD/CD Drive @ 16 RW with Nero 7.0 + BURN

- Windows XP Professional Operating System

 

Monitor Minimum Required Specifications:

- 2 MB High Contrast 1600 x 1200

- 21 inch Display

 

 


 

Generator Specifications:

 

20 or 30 KW High Frequency Generator with Anatomical Programs.
Generator Console

- Higher frequency for

  reduced radiation exposure.

- Separate generator cabinet

  and operator's console

- Tube protection circuit.

- Compact high voltage

  transformer is fitted in the

  generator cabinet.

- Optional APR (easy preset

  techniques by anatomical

  region selection) operator

  console.

- Optional AEC (automatic

  exposure console).

- Optional Buckey Control.

 

 

Specs  HF
Output Power Technique Factors 20 or 30 kW
400 mA, 125 kVp
mA Range
kVp Range  
Time
25 to 400 mA
40 to 125 kVp
2ms to 6 sec.
Input Power Single Phase 188/250 VAC
65A Breaker
Weight (Cabinet) 150lb (68kg)

 



 

Brochure

The brochure is available in high quality pdf format for printing.  Each image will open in a new window in adobe acrobat.  Please select an image to the right to begin.  Please note that the images are high quality and will require a high speed connection for faster download.

Eco21 Vet  Brochure Front Eco21 Vet  Brochure Back
  Brochure Front
pdf format
2.3 MB
Brochure Back
pdf format
2.6 MB

 

HOME | Company Information | Sales | Support | Contact Information
Toll Free: 1-866-RAYMAX1
Copyright © 2011.  Raymax Medical.  All Rights Reserved
Raymax Medical
20 Strathearn Avenue Unit #3
Brampton, Ontario, Canada L6T 4P7
Toll Free:  1-866-RAYMAX1
Tel:  1-905-791-3020
Fax:  1-905-791-3375
sales@raymaxmedical.com
www.raymaxmedical.com